BSQKQ - CHOPPED STRAND
- MSDS: BSQKQ
- Manufacturer: PPG INDUSTRIES INC
- Product Name: CHOPPED STRAND
- National Stock Number: 5620-00N040371
Product Identification
Product ID:CHOPPED STRAND
MSDS Date:11/25/1991
FSC:5620
NIIN:00N040371
MSDS Number: BSQKQ
Responsible Party
PITTSBURGH, PA 15272
US
Emergency Phone: 304-843-1300
Info Phone: 412-434-4110
Cage: 47695
Contractor
Telephone: 1-800-245-2974 (CAL HYPO)
Cage: 47695
Ingredients
FIBROUS GLASS (CONSISTING PRINCIPALLY OF OXIDES OF SILICON,
RTECS: LK3651000
Fraction By Weight: >84.5%
OSHA PEL 5 MG/M3 RDUST
ACGIH TLV: 10 MG/M3
AMORPHOUS VITREOUS STATE)
RTECS: 9999999ZZ
SIZING (SURFACE SIZING)
Fraction By Weight: <2.5%
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: 0-15%
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EXPOS TO GLASS FIBERS SOMETIMES
CAUSES IRRIT OF SKIN &, LESS FREQUENTLY, IRRIT OF EYES, NOSE OR
THROAT W/RASH, ITCHING, CONJUNCT, COUGHING & SNEEZING. CHRONIC:A
NUMBER OF EPIDEMIOLOGY STUDIES, D ONE OVER MANY YRS, OF WORKERS
EMPLOYED FOR UP TO 40 YRS IN MANUFACTURE OF FIBER GLASS HAVE SHOWN
NO (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:EVID OF INCR IN EITHER
MALIGNANT/NON-MALIGNANT RESP DISEASE ATTRIBUTABLE TO EXPOS TO FIBER
GLASS. HOWEVER, RECENT STUDIES HAVE SHOWN SLIGHT INCR IN LUNG
CANCER AMONG WORKERS EMPLOYED IN MANUF ACTURE OF GLASS WOOL &
MINERAL WOOL INSULATION PRODS. THOSE SAME STUDIES SHOWED NO EVID OF
A SIMILAR EFT (SUPP DATA)
Medical Cond Aggravated by Exposure:NONE KNOWN.
First Aid
First Aid:EYES:FLUSH W/CLEAR WATER FOR AT LEAST 15 MINS. SEEK MEDICAL
ATTENTION. SKIN:RINSE CONTACTED AREAS W/ROOM TEMPERATURE TO COOL
WATER, THEN WASH GENTLY W/MILD SOAP. IF FIBER GLASS BECOMES
IMBEDDED, SEEK MEDICAL ATTENTION. INGEST:CALL MD IMMEDIATELY .
INHAL: REMOVE TO FRESH AIR SUPPORT BREATHING (GIVE O2/ARTIFICIAL
RESPIRATION ).
Fire Fighting
Flash Point:NON-BURNING
Extinguishing Media:USE MEDIA SUITABLE FOR SURROUNDING FIRE CONDITIONS
.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT APPLICABLE.
Accidental Release
Spill Release Procedures:NO SPECIAL PRECAUTIONS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:NONE KNOWN.
Other Precautions:NONE KNOWN.
Exposure Controls
Respiratory Protection:NONE NORMALLY REQUIRED. IF AIRBORNE FIBER GLASS
CONCENTRATIONS EXCEED PERMISSIBLE EXPOSURE LEVELS, NIOSH/MSHA
APPROVED RESPIRATORY PROTECTION FOR NUISANCE DUSTS IN ACCORDANCE
W/OSHA 1910.134 SHOULD BE PROVIDED.
Ventilation:USE LOCAL EXHAUST VENTILATION IF NECESSARY TO MAINTAIN
AIRBORNE LEVELS TO BELOW ESTABLISHED LIMITS.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APRV CHEMICAL WORKERS GOGGLES (FP N
Other Protective Equipment:USE OF LONG SLEEVED SHIRTS, BUTTONED TO FIT
LOOSELY AT NECK & WRISTS & LONG PANTS WILL MAXIMIZE COMFORT.
Work Hygienic Practices:GOOD PERSONAL HYGIENE WILL MAXIMIZE COMFORT.
Supplemental Safety and Health
APPEAR/ODOR:A SPECIFIED LENGTH, HAVING NO ODOR; NORMALLY NO FIBERS
SMALLER THAN 6 MICRONS DIAMETER. EFTS OF OVEREXP:AMONG CONTINUOUS
FILAMENT FIBER GLASS WORKERS. THIS PRODUCT IS A CONTINUOUS FILAMENT
FIBER GLASS PRODUCT.
Chemical Properties
Melt/Freeze Pt:M.P/F.P Text:1472F,800C
Spec Gravity:2.59 BARE GLASS
Solubility in Water:INSOLUBLE
Appearance and Odor:YELLOW-WHITE TO WHITE FIBERS BOUND TOGETHER IN
STRANDS & CHOPPED TO (SUPP DATA)
Percent Volatiles by Volume:0
Stability
Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:IN A SUSTANIED FIRE, BINDERS MAY
DECOMPOSE RELEASING HAZARDOUS PRODUCTS OF COMBUSTION.
Disposal
Waste Disposal Methods:DISPOSE OF AS SOLID WASTE IN ACCORDANCE W/LOCAL,
STATE & FEDERAL REGULATIONS. NOT CONSIDRED A HAZARDOUS WASTE UNDER
FEDERL "RCRA" REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.